This page is part of archived documentation for openHAB 2.5. Go to the current stable version
# EcoTouch Binding v1
The openHAB EcoTouch binding allows interaction with a heat pump.
# Prerequisites
Make sure the display unit of the heat pump is connected to the network and that the network settings are configured. By default, the heat pump uses DHCP.
# Binding Configuration
The binding can be configured in the file services/ecotouch.cfg
.
Property | Default | Required | Description |
---|---|---|---|
ip | Yes | ip or DNS name of the heat pump | |
username | waterkotte | No | username for login |
password | waterkotte | No | password for login |
NOTE: Since Waterkotte Display software version 1.6.xx, the username/password
default value is waterkotte
. Prior to that, the username default was admin
and the password default was wtkadmin
.
# Item Configuration
The binding configuration format is simple and looks like this:
ecotouch="<eventType>"
where <eventType>
is one of the following values:
Description | <eventType> | ItemClass | Write | Notes |
---|---|---|---|---|
Außentemperatur | temperature_outside | number | ||
Außentemperatur gemittelt über 1h | temperature_outside_1h | number | ||
Außentemperatur gemittelt über 24h | temperature_outside_24h | number | ||
Quelleneintrittstemperatur | temperature_source_in | number | Ai1 Geo only | |
Quellenaustrittstemperatur | temperature_source_out | number | Ai1 Geo only | |
Umgebungstemperatur | temperature_surrounding | number | Ai1 Air only | |
Verdampfungstemperatur | temperature_evaporation | number | ||
Sauggastemperatur | temperature_suction | number | Ai1 Geo only | |
Sauggas | temperature_suction_air | number | Ai1 Air only | |
Ölsumpf | temperature_sump | number | Ai1 Air only | |
Verdampfungsdruck | pressure_evaporation | number | ||
Temperatur Rücklauf Soll | temperature_return_set | number | ||
Temperatur Rücklauf | temperature_return | number | ||
Temperatur Vorlauf | temperature_flow | number | ||
Kondensationstemperatur | temperature_condensation | number | ||
Kondensationsdruck | pressure_condensation | number | ||
Speichertemperatur | temperature_storage | number | ||
Raumtemperatur | temperature_room | number | ||
Raumtemperatur gemittelt über 1h | temperature_room_1h | number | ||
Warmwassertemperatur | temperature_water | number | ||
Pooltemperatur | temperature_pool | number | ||
Solarkollektortemperatur | temperature_solar | number | ||
Solarkreis Vorlauf | temperature_solar_flow | number | ||
Ventilöffnung elektrisches Expansionsventil % | position_expansion_valve | number | ||
elektrische Leistung Verdichter | power_compressor | number | ||
abgegebene thermische Heizleistung der Wärmepumpe | power_heating | number | ||
abgegebene thermische KälteLeistung der Wärmepumpe | power_cooling | number | ||
COP Heizleistung | cop_heating | number | ||
COP Kälteleistung | cop_cooling | number | ||
Aktuelle Heizkreistemperatur | temperature_heating_return | number | ||
Geforderte Temperatur im Heizbetrieb | temperature_heating_set | number | ||
Sollwertvorgabe Heizkreistemperatur | temperature_heating_set2 | number | yes | |
Aktuelle Kühlkreistemperatur | temperature_cooling_return | number | ||
Geforderte Temperatur im Kühlbetrieb | temperature_cooling_set | number | ||
Sollwertvorgabe Kühlbetrieb | temperature_cooling_set2 | number | yes | |
Sollwert Warmwassertemperatur | temperature_water_set | number | ||
Sollwertvorgabe Warmwassertemperatur | temperature_water_set2 | number | yes | |
Sollwert Poolwassertemperatur | temperature_pool_set | number | ||
Sollwertvorgabe Poolwassertemperatur | temperature_pool_set2 | number | yes | |
geforderte Verdichterleistung | compressor_power | number | ||
% Heizungsumwälzpumpe | percent_heat_circ_pump | number | ||
% Quellenpumpe | percent_source_pump | number | ||
% Leistung Verdichter | percent_compressor | number | ||
Heizkurve - Norm-Aussen-Temp (Auslegungstemp) | nviNormAussen | number | yes | |
Heizkurve - Temp Heizkreis bei Auslegungstemp | nviHeizkreisNorm | number | yes | |
Heizkurve - Temp Heizgrenze | nviTHeizgrenze | number | yes | |
Heizkurve - Temp Heizkreis Heizgrenze | nviTHeizgrenzeSoll | number | yes | |
Heizkurve - max. VL-Temp | maxVLTemp | number | yes | |
Kühlen Einschalt-Aussentemp | coolEnableTemp | number | yes | |
geforderte Kühltemperatur | nviSollKuehlen | number | ||
Firmware-Version Regler | version_controller | number | ||
Build-Nr. Regler | version_controller_build | number | ||
Bios-Version Regler | version_bios | number | ||
Datum: Tag | date_day | number | ||
Datum: Monat | date_month | number | ||
Datum: Jahr | date_year | number | ||
Uhrzeit: Stunde | time_hour | number | ||
Uhrzeit: Minute | time_minute | number | ||
Betriebsstunden Verdichter 1 | operating_hours_compressor1 | number | ||
Betriebsstunden Verdichter 2 | operating_hours_compressor2 | number | ||
Betriebsstunden Heizungsumwälzpumpe | operating_hours_circulation_pump | number | ||
Betriebsstunden Quellenpumpe | operating_hours_source_pump | number | ||
Betriebsstunden Solarkreis | operating_hours_solar | number | ||
Handabschaltung Heizbetrieb | enable_heating | switch | yes | |
Handabschaltung Kühlbetrieb | enable_cooling | switch | yes | |
Handabschaltung Warmwasserbetrieb | enable_warmwater | switch | yes | |
Handabschaltung Pool_Heizbetrieb | enable_pool | switch | yes | |
Status der Wärmepumpenkomponenten | state | number | State as a number, see below for possible mapping. | |
Status Quellenpumpe | state_sourcepump | switch | ||
Status Heizungsumwälzpumpe | state_heatingpump | switch | ||
Status Freigabe Regelung EDV / Magnetventil | state_evd | switch | ||
Status Verdichter 1 | state_compressor1 | switch | ||
Status Verdichter 2 | state_compressor2 | switch | ||
Status externer Wärmeerzeuger | state_extheater | switch | ||
Status Alarmausgang | state_alarm | switch | ||
Status Motorventil Kühlbetrieb | state_cooling | switch | ||
Status Motorventil Warmwasser | state_water | switch | ||
Status Motorventil Pool | state_pool | switch | ||
Status Solarbetrieb | state_solar | switch | ||
Status 4-Wege-Ventil | state_cooling4way | switch | ||
Temperaturanpassung für die Heizung -2,0 / +2,0 | adapt_heating | number | yes | -2 bis +2 (0,5)---> 0 bis 8 |
Handschaltung Heizungspumpe | manual_heatingpump | yes | (H-0-A) H= manuell ein (Handschaltung), 0= aus, A= Automatik | |
Handschaltung Quellenpumpe | manual_sourcepump | yes | (H-0-A) | |
Handschaltung Solarpumpe 1 | manual_solarpump1 | yes | (H-0-A) | |
Handschaltung Solarpumpe 2 | manual_solarpump2 | yes | (H-0-A) | |
Handschaltung Speicherladepumpe | manual_tankpump | yes | (H-0-A) | |
Handschaltung Brauchwasserventil | manual_valve | yes | (H-0-A) | |
Handschaltung Poolventil | manual_poolvalve | yes | (H-0-A) | |
Handschaltung Kühlventil | manual_coolvalve | yes | (H-0-A) | |
Handschaltung Vierwegeventil | manual_4wayvalve | yes | (H-0-A) | |
Handschaltung Multiausgang Ext. | manual_multiext | yes | (H-0-A) |
# Mappings
Heatpump event type "state" can be mapped to strings. Different heatpump models seem to have slightly different state values. Mappings for the Ai1 Geo have been copied from here (opens new window).
State | Ai1 Geo | Ai1 Air |
---|---|---|
0 | aus | aus |
1 | nur Solepumpe 1 | |
2 | nur Heizkreispumpe 2 | Standby |
3 | unbekannt | |
7 | unbekannt | |
10 | Heizbetrieb | |
15 | Heizbetrieb | |
131 | Naturkühlung | |
256 | Vorlauf Warmwasser | Vorlauf Warmwasser |
258 | Nachlauf Warmwasser | Nachlauf Warmwasser |
259 | unbekannt 259 vor WW Bereitung | |
263 | unbekannt 263 vor WW Bereitung | |
266 | Warmwasserbereitung | |
271 | Warmwasserbereitung |
# Examples
# Items examples
/* Waterkotte EcoTouch heat pump DEMO */
Group Heatpump
Group Heatpump_outside
Group Heatpump_source
Group Heatpump_control
Group Heatpump_water
Group Heatpump_heating
Group Heatpump_power
Group Heatpump_state
Number Chart_Period "Chart Period"
Number HeatPump_Temperature_3 "Wärmepumpe Außentemperatur [%.1f °C]" <temperature> (Heatpump,Heatpump_outside) { ecotouch="temperature_outside" }
Number HeatPump_Temperature_4 "Wärmepumpe Außentemperatur 1h [%.1f °C]" <temperature> (Heatpump,Heatpump_outside) { ecotouch="temperature_outside_1h" }
Number HeatPump_Temperature_5 "Wärmepumpe Außentemperatur 24h [%.1f °C]" <temperature> (Heatpump,Heatpump_outside) { ecotouch="temperature_outside_24h" }
Number HeatPump_Temperature_6 "Wärmepumpe Quelleneintrittstemperatur [%.1f °C]" <temperature> (Heatpump,Heatpump_source) { ecotouch="temperature_source_in" }
Number HeatPump_Temperature_7 "Wärmepumpe Quellenaustrittstemperatur [%.1f °C]" <temperature> (Heatpump,Heatpump_source) { ecotouch="temperature_source_out" }
Number HeatPump_Temperature_8 "Wärmepumpe Vorlauf [%.1f °C]" <temperature> (Heatpump,Heatpump_control) { ecotouch="temperature_flow" }
Number HeatPump_Temperature_9 "Wärmepumpe Rücklauf [%.1f °C]" <temperature> (Heatpump,Heatpump_control) { ecotouch="temperature_return" }
Number HeatPump_Temperature_10 "Wärmepumpe Rücklauf Soll [%.1f °C]" <temperature> (Heatpump,Heatpump_control) { ecotouch="temperature_return_set" }
Number HeatPump_Temperature_11 "Wärmepumpe Warmwasser Ist [%.1f °C]" <temperature> (Heatpump,Heatpump_water) { ecotouch="temperature_water" }
Number HeatPump_Temperature_12 "Wärmepumpe Warmwasser Soll [%.1f °C]" <temperature> (Heatpump,Heatpump_water) { ecotouch="temperature_water_set" }
Number HeatPump_Temperature_13 "Wärmepumpe Warmwasser Soll2 [%.1f °C]" <temperature> (Heatpump,Heatpump_water) { ecotouch="temperature_water_set2" }
Number HeatPump_Temperature_14 "Wärmepumpe Heizung Ist [%.1f °C]" <temperature> (Heatpump,Heatpump_heating) { ecotouch="temperature_heating_return" }
Number HeatPump_Temperature_15 "Wärmepumpe Heizung Soll [%.1f °C]" <temperature> (Heatpump,Heatpump_heating) { ecotouch="temperature_heating_set" }
Number HeatPump_Temperature_16 "Wärmepumpe Heizung Soll2 [%.1f °C]" <temperature> (Heatpump,Heatpump_heating) { ecotouch="temperature_heating_set2" }
Number HeatPump_power_1 "Wärmepumpe elektrische Leistung [%.1f kW]" <energy> (Heatpump,Heatpump_power) { ecotouch="power_compressor" }
Number HeatPump_power_2 "Wärmepumpe thermische Leistung [%.1f kW]" <energy> (Heatpump,Heatpump_power) { ecotouch="power_heating" }
Number HeatPump_state "Wärmepumpe Status [%i]" <settings> (Heatpump) { ecotouch="state" }
Number HeatPump_state_sourcepump "Wärmepumpe Status Quellenpumpe [%i]" <settings> (Heatpump,Heatpump_state) { ecotouch="state_sourcepump" }
Number HeatPump_state_heatingpump "Wärmepumpe Status Heizungsumwälzpumpe [%i]" <settings> (Heatpump,Heatpump_state) { ecotouch="state_heatingpump" }
Number HeatPump_state_compressor1 "Wärmepumpe Status Kompressor [%i]" <settings> (Heatpump,Heatpump_state) { ecotouch="state_compressor1" }
Number HeatPump_state_water "Wärmepumpe Status Motorventil Warmwasser[%i]" <settings> (Heatpump,Heatpump_state) { ecotouch="state_water" }
# Sitemap examples
Frame label="Waterkotte" {
Text item=HeatPump_Temperature_3 {
Frame {
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
Chart item=Heatpump_outside period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
Chart item=Heatpump_outside period=D refresh=60000 visibility=[Chart_Period==1]
Chart item=Heatpump_outside period=W refresh=60000 visibility=[Chart_Period==2]
}
}
Text item=HeatPump_Temperature_6 {
Frame {
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
Chart item=Heatpump_source period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
Chart item=Heatpump_source period=D refresh=60000 visibility=[Chart_Period==1]
Chart item=Heatpump_source period=W refresh=60000 visibility=[Chart_Period==2]
}
}
Text item=HeatPump_Temperature_7 {
Frame {
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
Chart item=Heatpump_source period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
Chart item=Heatpump_source period=D refresh=60000 visibility=[Chart_Period==1]
Chart item=Heatpump_source period=W refresh=60000 visibility=[Chart_Period==2]
}
}
Text item=HeatPump_Temperature_8 {
Frame {
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
Chart item=Heatpump_control period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
Chart item=Heatpump_control period=D refresh=60000 visibility=[Chart_Period==1]
Chart item=Heatpump_control period=W refresh=60000 visibility=[Chart_Period==2]
}
}
Text item=HeatPump_Temperature_9 {
Frame {
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
Chart item=Heatpump_control period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
Chart item=Heatpump_control period=D refresh=60000 visibility=[Chart_Period==1]
Chart item=Heatpump_control period=W refresh=60000 visibility=[Chart_Period==2]
}
}
Text item=HeatPump_Temperature_10 {
Frame {
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
Chart item=Heatpump_control period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
Chart item=Heatpump_control period=D refresh=60000 visibility=[Chart_Period==1]
Chart item=Heatpump_control period=W refresh=60000 visibility=[Chart_Period==2]
}
}
Text item=HeatPump_Temperature_11 {
Frame {
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
Chart item=Heatpump_water period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
Chart item=Heatpump_water period=D refresh=60000 visibility=[Chart_Period==1]
Chart item=Heatpump_water period=W refresh=60000 visibility=[Chart_Period==2]
}
}
Text item=HeatPump_Temperature_12 {
Frame {
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
Chart item=Heatpump_water period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
Chart item=Heatpump_water period=D refresh=60000 visibility=[Chart_Period==1]
Chart item=Heatpump_water period=W refresh=60000 visibility=[Chart_Period==2]
}
}
Text item=HeatPump_Temperature_13 {
Frame {
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
Chart item=Heatpump_water period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
Chart item=Heatpump_water period=D refresh=60000 visibility=[Chart_Period==1]
Chart item=Heatpump_water period=W refresh=60000 visibility=[Chart_Period==2]
}
}
Text item=HeatPump_Temperature_14 {
Frame {
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
Chart item=Heatpump_heating period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
Chart item=Heatpump_heating period=D refresh=60000 visibility=[Chart_Period==1]
Chart item=Heatpump_heating period=W refresh=60000 visibility=[Chart_Period==2]
}
}
Text item=HeatPump_Temperature_15 {
Frame {
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
Chart item=Heatpump_heating period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
Chart item=Heatpump_heating period=D refresh=60000 visibility=[Chart_Period==1]
Chart item=Heatpump_heating period=W refresh=60000 visibility=[Chart_Period==2]
}
}
Text item=HeatPump_Temperature_16 {
Frame {
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
Chart item=Heatpump_heating period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
Chart item=Heatpump_heating period=D refresh=60000 visibility=[Chart_Period==1]
Chart item=Heatpump_heating period=W refresh=60000 visibility=[Chart_Period==2]
}
}
Text item=HeatPump_power_1 {
Frame {
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
Chart item=Heatpump_power period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
Chart item=Heatpump_power period=D refresh=60000 visibility=[Chart_Period==1]
Chart item=Heatpump_power period=W refresh=60000 visibility=[Chart_Period==2]
}
}
Text item=HeatPump_power_2 {
Frame {
Switch item=Chart_Period label="Chart Period" mappings=[0="Hour", 1="Day", 2="Week"]
Chart item=Heatpump_power period=h refresh=60000 visibility=[Chart_Period==0, Chart_Period=="Uninitialized"]
Chart item=Heatpump_power period=D refresh=60000 visibility=[Chart_Period==1]
Chart item=Heatpump_power period=W refresh=60000 visibility=[Chart_Period==2]
}
}
}
# Gallery
The following charts are created via the rrd4j chart and heatpump bundle.