This page is part of archived documentation for openHAB 2.5. Go to the current stable version
# ISY Binding
This is a openHAB binding for the Universal Devices ISY 994i router and PLM. Universal Devices offers a Java SDK for external programs to communicate with the router. Alternatives include an extensive REST API. See details at https://www.universal-devices.com/isy-developers/ (opens new window).
# Items Configuration with ISY Binding Details
The following settings can be added to the Items definition.
- ctrl - Controller address in the format "x.y.z.w". This can be the address of a ISY Insteon Scene. Insteon addresses use the first three bytes and the last byte identified a particular capability of the device.
- type - This can be used to select device types with special configuration needs. See the "Device Types" section below.
- cmd - Specific ISY control to send to the ISY router as a command, ST is the default if left out
- addr - The Insteon address to monitor for the change. A scene does not report a status change, only the devices in the scene do. Specify the controller of the scene here. Defaults to the controller address if left out
# Device Types
You can specify a specific device type to let the binding know that a device is a special type. This is done using the "type=" configuation item in the binding.
There are currently 3 types available:
- thermostat - required to perform temperature calculations properly
- lock - locks use the security command instead of the normal off/on commands
- heartbeat - several battery powered sensors send a heartbeat. This is just a ST (status) with value 255, and it means that the sensor is still alive. To make rules easier, you can define these as type=heartbeat with an item type of DateTime, and it will update with the current time every time the heartbeat is received. You can then check the item using a rule to see if the DateTime item is too old.
# Item Examples
/* Insteon-enabled thermostat. Note "type=thermostat" to ensure proper temp calculations, and cmd=CLISPH to use the ISY setpoint heat value instead of status */
Number Temperature_Indoor "Inside [%.2f °F]" <temperature> (All) {isy="ctrl=29.24.98.1,type=thermostat,cmd=ST"}
Number Temperature_Setpoint "Desired Temperature [%.2f °F]" <temperature> (All) {isy="ctrl=29.24.98.1,type=thermostat,cmd=CLISPH"}
/* Regular ISY scene id #12220, but look at device 30.CB.66.1 to get the scene status */
Switch Light_Hallway2 "Hallway" <switch> (GroundFloor,Lights) {isy="ctrl=12220,addr=30.CB.66.1"}
/* Regular ISY device, controlled directly (won't update scenes!)
Switch K_DiningRoom_Light "Dining Room Light" (GroundFloor,Lights) {isy="ctrl=F.C3.7C.1"}
/* ZWave lock. Note type=lock (makes it use the security commands necessary). The second (Number) entry watches the BATLVL value, which battery-powered devices use to report battery level in percent */
Switch BDoorLock "Back Door Lock" <lock> (Locks) {isy="ctrl=ZW004_1,type=lock"}
Number BDoorLock_Battery "Back Door Lock Battery [%d]" <battery> (Locks,BattLevels) {isy="ctrl=ZW004_1,cmd=BATLVL"}
/* Insteon FanLinc, set up with a Keypadlinc. 4 scenes - Off, Low, Med, High */
Switch LR_Fan_Off "LR Fan Off" (ISYScenes) {isy="ctrl=4622,addr=1c.e2.d1.3", autoupdate="false"}
Switch LR_Fan_Low "LR Fan Low" (ISYScenes) {isy="ctrl=20771,addr=1c.e2.d1.4", autoupdate="false"}
Switch LR_Fan_Med "LR Fan Med" (ISYScenes) {isy="ctrl=22031,addr=1c.e2.d1.5", autoupdate="false"}
Switch LR_Fan_High "LR Fan High" (ISYScenes) {isy="ctrl=11187,addr=1c.e2.d1.6", autoupdate="false"}
/* Insteon water sensor - it has 3 subdevices: 1 = dry, 2 = wet, 4 = heartbeat
The heartbeat device sends an "ON" (255) ST code as a heartbeat. With type=heartbeat, the binding
sends a DateTime value. You can use a rule to check that DateTime to see if you have received
a heartbeat recently */
Contact Water_Heater_Dry "Water Heater Sensor [MAP(watersensor-en.map):%s]" (Sensors) {isy="addr=25.AD.4F.1"}
DateTime Water_Heater_Heartbeat "Water Heater HB [%1$td.%1$tm.%1$tY %1$tH:%1$tM]" (Sensors) {isy="addr=25.AD.4F.4", type=heartbeat}
The transform file (watersensor-en.map) for the water sensor is:
CLOSED=Wet
OPEN=Dry
undefined=Unknown
-=Unknown
# ISY Binding Configuration
The following settings configure the ISY binding in the openhab.cfg file.
isy:refresh=60000 # refresh interval in milliseconds (optional, defaults to 60000 [1 minute])
isy:upnp=true # if true, use UPNP to communicate with the ISY 994i
isy:uuid=uuid:%your_uudid% # UUID of the ISY router
isy:ip=192.168.x.x # the hostname of the ISY router
isy:port=80 # the port of the ISY router
isy:user=user # the user of the ISY router
isy:password=password # the password of the ISY router